Four things, in the order we added them: buildings, fibre, routing, and the silicon that does the routing. Everything else the industry sells sits on top of one of the four, and we have consistently declined to sell it.

01 — Colocation

Halls we own, in buildings we own

We are the landlord, the electrician and the network. That is unusual and it is the whole argument: when a chiller fails at Grayling there is no third party to attend, and when a hall runs hot the person who signed for the mechanical design still works here.

Halls are sold by power, not by floor area, because power is the constraint and has been since 1997. We will tell you the installed headroom of a specific hall under NDA; we will not publish it, because published headroom is bid against.

Carrier-neutral without qualification. There are 31 networks on-net at the Ostrow Line meet-me and we compete with most of them.

Colocation specification
Rack density, standard4 – 12 kW, A+B feeds, shared containment
Rack density, high12 – 28 kW, rear-door heat exchanger
Rack density, engineeredto 42 kW, direct liquid, per-hall agreement
Cabinet600 × 1200 × 47U, or customer-supplied to our anchor pattern
ElectricalTwo independent utility feeds, 2N UPS, N+1 generation, 96 h fuel on site
MechanicalN+1 minimum; 2N in halls sold as 2N. Free cooling where the region allows it
Cold aisle8 – 24 °C, contained, ASHRAE-equivalent envelope
Availability99.999% at the busway, measured at the busway
AccessTwo-factor at the perimeter, mantrap at the hall, escorted first visit
Remote hands15 min acknowledged, 60 min actioned, 24 h

02 — IP transit

AS64502, full tables, no default

Transit is sold on commit, in credits, per megabit per month, on a term. There is no burst penalty structure and no 95th-percentile arithmetic designed to be misunderstood: you commit, you are billed on the commit, and overage is at the same unit rate as the commit.

The backbone is engineered to carry its busiest hour with any single span failed. We publish the utilisation curve quarterly, including the two spans that are currently above where we would like them.

  • BGP communities documented publicly
  • Blackhole community honoured at every edge
  • RPKI-validating, invalids dropped
  • IRR-filtered on customer sessions
  • Flowspec available on 100G+ commits
  • IPv6 at no additional charge, ever
Indicative transit rates
CommitPortRateTerm
Commit 1 Gbit/s10 GE0.9 credits / Mbit/s / month12 months
Commit 10 Gbit/s10 GE / 100 GE0.62 credits / Mbit/s / month12 months
Commit 100 Gbit/s100 GE LR40.31 credits / Mbit/s / month24 months
Commit 400 Gbit/s400 GE FR40.18 credits / Mbit/s / month36 months
Above 1 Tbit/s400/800 GEOn applicationNegotiated

Indicative only. Rates are in credits and are confirmed on a quotation against a specific port at a specific facility.

03 — Fibre and interconnect

Glass, and the right to dig

The backbone is ours: conduit, fibre, huts, and in eleven cases the field the conduit crosses. Buying the route rather than the capacity was an expensive decision taken in the early nineties by people who wanted the network to still be here now.

Interconnect inside our halls is a cross-connect, priced per connect per month, with no recurring charge for the first one in any new cage. Interconnect at an exchange is settlement-free under our open policy.

Transport specification
Backbone41,880 route-km, owned, not leased
Long-haul line rate400G and 800G coherent, 1.2T in trial on two spans
MetroDark fibre pairs, CWDM/DWDM, or managed wavelengths
SubseaFive systems; two owned outright, three on 25-year IRU
DiversityNo two contracted paths share a duct. Where they do, it is disclosed and dated
RestorationSub-50 ms on protected wavelengths; unprotected is unprotected

04 — Routing silicon

Seven generations, one customer

In 1988 the merchant parts available to us could not hold the table we needed, so we designed one that could. We have not missed a tape-out in nineteen years. The parts are not sold, licensed or sampled; they go into our line cards, our line cards go into our halls, and the effect reaches customers as latency and price rather than as a product.

The counter plane on SL-7 is larger than the forwarding requirement because Platform Defence specifies it that way. Defence observability is a design input at the same tier as line rate, which is unusual, and is the reason ICE runs in the fabric rather than beside it.

Silicon families
FamilyFirst siliconFunctionStatus
SL-11988Forwarding engineRetired 1996
SL-21993Forwarding engine, first in-house lookupRetired 2001
SL-31998Line card ASICRetired 2009
SL-42004Line card ASIC, first algorithmic lookupRetired 2018
SL-52010Forwarding plane, integrated schedulerOperating, MRH1 and OST1
SL-62017Forwarding plane, 400G nativeOperating, all regions
SL-72023Forwarding plane, 800G native, expanded counter planeOperating, ramping
SL-82028 (planned)In RTLTape-out slot contracted

Platform defence

ICE, as a property of the fabric

Barrier

At the edge

Ruleset applied at every peering and transit edge, promoted weekly. Barrier is coarse, fast and public: customers can see what it dropped on their prefixes.

Ward

At the customer boundary

Per-customer thresholds on the cage-facing port. Tuned by us, on our schedule, under the terms of the colocation agreement.

Sentry

Inside the hall

Operates within the hall boundary and is permitted to act there without an operator in the loop. Actions are reviewed within two hours and recorded in full.

Trace Operations maintains attribution on hostile activity across all fabrics and hands findings to Incident Command and to Regulatory & Lawful Access. Customers are not parties to that process and do not receive trace product.

We are hiring into all three tiers →